Products |
>> |
FDA-Centrifugal Fan |
>> |
FDA-CY |
|
|
|
|
Model |
A1 (mm) |
A2 (mm) |
B (mm) |
C (mm) |
D (mm) |
E (mm) |
F1 (mm) |
F2 (mm) |
T (mm) |
FDA150C15E2-CY |
150 |
150 |
120 |
90 |
150 |
97 |
150 |
246 |
10 |
FDA180C15E2-CY |
150 |
150 |
120 |
100 |
150 |
102.4 |
183 |
246 |
10 |
FDA200C20E2-CY |
200 |
180 |
160 |
120 |
200 |
126 |
203 |
306 |
10 |
Model |
G1 (mm) |
G2 (mm) |
H1(mm) |
H2 (mm) |
H3 (mm) |
M1 (mm) |
M2 (mm) |
N (mm) |
Weight (kg) |
FDA150C15E2-CY |
276 |
327 |
283 |
336 |
181 |
120 |
222 |
26 |
10.80 |
FDA180C15E2-CY |
297 |
350 |
311 |
425 |
225 |
150 |
222 |
26 |
22.10 |
FDA200C20E2-CY |
348 |
437 |
325 |
451 |
210 |
135 |
276 |
32 |
30.80 |
|
|
|
High quality motor |
|
Metal forward curve centifiugal blade |
|
Metal frame painted |
|
Double ball bearing for long life runing |
|
other voltage version, are customized to meet |
|
specific customer requirement. |
|
Used for cooling machine, exhaust air, |
|
Special as inflator for advertisement |
|
|
|
Dimension and Installation |
|
|
|
|
|
Model |
Voltage (VAC) |
Freq (Hz) |
Power (Watt) |
Current (Amp) |
Speed (RPM) |
Cap (uF/V) |
Airflow (cbm/h) |
Airpressure (Pa) |
Noise(dB) |
FDA150C15E2-CY |
220-240 |
50/60 |
360-370 |
1.80-2.20 |
2930-3400 |
1-phase |
750-880 |
570-825 |
85-87 |
FDA150C15D2-CY |
380-400 |
50/60 |
360-370 |
1.80-2.20 |
2930-3400 |
3-phases |
750-880 |
570-825 |
85-87 |
FDA180C15E2-CY |
220-240 |
50/60 |
740-750 |
3.60-5.30 |
2800-3300 |
1-phase |
1380-1620 |
941-1344 |
88-90 |
FDA180C15D2-CY |
380-400 |
50/60 |
740-750 |
2.50-3.30 |
2800-3300 |
3-phases |
1380-1620 |
941-1344 |
88-90 |
FDA200C15E2-CY |
220-240 |
50/60 |
1400-1500 |
8.50-10.60 |
2850-3380 |
1-phase |
1860-2680 |
1442-2030 |
90-92 |
FDA200C15D2-CY |
380-400 |
50/60 |
1400-1500 |
4.60-7.00 |
2850-3380 |
3-phases |
1860-2680 |
1442-2030 |
90-92 |
|
|
Description and Application field |
|
|
|
Fan: Backward curve centrifugal fan with external rotor motor, water-proof |
|
Material: Aluminum blade and metal frame |
|
Insulation Resistance:10MΩ at 500VDC between lead and frame |
|
Dielectric Strength:1 min at 1500VAC/50-60Hz ,current〈5mA |
|
Operation voltage: 85V to 125V for 110V and 190V to 250V for 220V |
|
Operation Temperature: -10° C to 60° C |
|
Operation Humidity: 20% to 85% |
|
The specification as table here are the general data, these are reference only, |
|
the actual products manufactured by Fengda |
|
Other voltage version, are customized to meet specific customer requirement. |
|
|
|
|