Products |
>> |
FDA-Axial Fan |
>> |
FDA-ST |
|
|
|
|
|
Dimension and Installation |
|
|
|
Model |
A (mm) |
B (mm) |
C (mm) |
D (mm) |
E (mm) |
N (mm) |
Weight(kgs) |
FDA200-ST |
246 |
205 |
215 |
80 |
169 |
7 |
2.20 |
FDA250-ST |
290 |
251 |
265 |
92 |
214 |
7 |
2.90 |
FDA300-ST |
352 |
302 |
315 |
97 |
251 |
9 |
4.20 |
FDA350-ST |
405 |
345 |
367 |
122 |
297 |
9 |
5.80 |
FDA400-ST |
480 |
420 |
416 |
133 |
332 |
9 |
7.00 |
FDA450-ST |
560 |
500 |
468 |
141 |
368 |
11 |
9.00 |
FDA500-ST |
600 |
540 |
517 |
145 |
406 |
11 |
12.00 |
FDA550-ST |
675 |
615 |
575 |
163 |
445 |
11 |
16.00 |
FDA630-ST |
756 |
700 |
650 |
185 |
516 |
11 |
21.80 |
|
|
|
|
Model |
Voltage (VAC) |
Freq (Hz) |
Power (Watt) |
Current (Amp) |
Speed (RPM) |
Cap (uF/V) |
Airflow (cbm/h) |
Airpressure (Pa) |
Noise(dB) |
FDA200E2-ST |
220-240 |
50/60 |
70-80 |
0.33-0.35 |
2400-2600 |
2/450 |
1650-1745 |
43-46 |
63-65 |
FDA200D2-ST |
380-400 |
50/60 |
40-45 |
0.08-0.10 |
2400-2600 |
3 phases |
1650-1745 |
43-46 |
63-65 |
FDA200E4-ST |
220-240 |
50/60 |
55-60 |
0.24-0.26 |
1420-1600 |
1/450 |
800-910 |
32-35 |
49-52 |
FDA200D4-ST |
380-400 |
50/60 |
40-43 |
0.08-0.10 |
1420-1600 |
3 phases |
800-910 |
32-35 |
49-52 |
FDA250E2-ST |
220-240 |
50/60 |
110-115 |
0.50-0.55 |
2500-2900 |
3/450 |
2380-2552 |
51-53 |
64-68 |
FDA250D2-ST |
380-400 |
50/60 |
100-110 |
0.23-0.25 |
2500-2900 |
3 phases |
2380-2552 |
51-53 |
64-68 |
FDA250E4-ST |
220-240 |
50/60 |
65-70 |
0.30-0.33 |
1380-1700 |
2/450 |
1700-1800 |
38-40 |
54-58 |
FDA250D4-ST |
380-400 |
50/60 |
45-60 |
0.15-0.20 |
1380-1700 |
3 phases |
1700-1800 |
38-40 |
54-58 |
FDA300E2-ST |
220-240 |
50/60 |
130-170 |
0.58-0.70 |
2600-2900 |
4/450 |
3400-3505 |
58-68 |
68-70 |
FDA300D2-ST |
380-400 |
50/60 |
110-115 |
0.32-0.40 |
2600-2900 |
3 phases |
3400-3505 |
58-68 |
68-70 |
FDA300E4-ST |
220-240 |
50/60 |
80-90 |
0.47-0.49 |
1420-1700 |
3/450 |
2550-2608 |
42-49 |
56-60 |
FDA300D4-ST |
380-400 |
50/60 |
80-85 |
0.21-0.25 |
1420-1700 |
3 phases |
2550-2608 |
42-49 |
56-60 |
FDA350E2-ST |
220-240 |
50/60 |
240-250 |
1.10-1.15 |
2400-2500 |
8/450 |
4550-4650 |
77-85 |
70-72 |
FDA350D2-ST |
380-400 |
50/60 |
240-250 |
0.45-0.55 |
2400-2500 |
3 phases |
4550-4650 |
77-85 |
70-72 |
FDA350E4-ST |
220-240 |
50/60 |
125-130 |
0.62-0.70 |
1380-1700 |
4/450 |
3550-3650 |
58-65 |
58-62 |
FDA350D4-ST |
380-400 |
50/60 |
105-125 |
0.27-0.30 |
1380-1700 |
3 phases |
3550-3650 |
58-65 |
58-62 |
FDA400E4-ST |
220-240 |
50/60 |
160-188 |
0.75-0.80 |
1420-1700 |
6/450 |
4650-4900 |
73-78 |
68-72 |
FDA400D4-ST |
380-400 |
50/60 |
120-160 |
0.41-0.43 |
1420-1700 |
3 phases |
4650-4900 |
73-78 |
68-72 |
FDA400E6-ST |
220-240 |
50/60 |
128-138 |
0.63-0.68 |
950-1050 |
4/450 |
3860-4100 |
57-63 |
68-73 |
FDA400D6-ST |
380-400 |
50/60 |
110-128 |
0.28-0.34 |
950-1050 |
3 phases |
3860-4100 |
57-63 |
68-73 |
FDA450E4-ST |
220-240 |
50/60 |
220-300 |
0.95-1.35 |
1300-1500 |
8/450 |
5600-6500 |
85-91 |
72-76 |
FDA450D4-ST |
380-400 |
50/60 |
230-280 |
0.68-0.73 |
1300-1500 |
3 phases |
5600-6500 |
85-91 |
72-76 |
FDA450E6-ST |
220-240 |
50/60 |
130-140 |
0.60-0.65 |
950-1050 |
6/450 |
4400-5400 |
62-72 |
62-66 |
FDA450D6-ST |
380-400 |
50/60 |
120-130 |
0.35-0.40 |
950-1050 |
3 phases |
4400-5400 |
62-72 |
62-66 |
FDA500E4-ST |
220-240 |
50/60 |
270-280 |
1.20-1.70 |
1340-1550 |
10/450 |
6550-7500 |
92-96 |
76-79 |
FDA500D4-ST |
380-400 |
50/60 |
330-395 |
0.74-0.80 |
1380-1610 |
3 phases |
6550-7500 |
92-96 |
76-79 |
FDA500E6-ST |
220-240 |
50/60 |
160-170 |
0.88-0.95 |
900-1000 |
6/450 |
5500-5800 |
73-78 |
65-68 |
FDA500D6-ST |
380-400 |
50/60 |
120-130 |
0.40-0.45 |
920-1030 |
3 phases |
5500-5800 |
73-78 |
65-68 |
FDA550E4-ST |
220-240 |
50/60 |
420-510 |
1.90-2.20 |
1340-1550 |
12/450 |
7500-7900 |
99-108 |
78-82 |
FDA550D4-ST |
380-400 |
50/60 |
415-445 |
1.00-1.08 |
1370-1600 |
3 phases |
7500-7900 |
99-108 |
78-82 |
FDA550E6-ST |
220-240 |
50/60 |
320-370 |
1.30-1.35 |
910-1000 |
8/450 |
6580-6800 |
84-92 |
67-71 |
FDA550D6-ST |
380-400 |
50/60 |
305-355 |
0.88-0.95 |
930-1020 |
3 phases |
6580-6800 |
84-92 |
67-71 |
FDA630E4-ST |
220-240 |
50/60 |
560-600 |
2.50-2.90 |
1310-1460 |
12/450 |
8990-9500 |
107-120 |
82-87 |
FDA630D4-ST |
380-400 |
50/60 |
410-560 |
1.10-1.85 |
1340-1490 |
3 phases |
8990-9500 |
107-120 |
82-87 |
FDA630E6-ST |
220-240 |
50/60 |
380-430 |
1.80-2.10 |
890-950 |
8/450 |
900-8500 |
91-105 |
72-74 |
FDA630D6-ST |
380-400 |
50/60 |
250-300 |
0.68-0.75 |
910-980 |
3 phases |
900-8500 |
91-105 |
72-74 |
|
|
Description and Application field |
|
|
|
External rotor motor with metal blades and are suitable for different housing frame |
|
Double ball bearing for long life runing |
|
Insulation Resistance:10MΩ at 500VDC between lead and frame |
|
Dielectric Strength:1 min at 1500VAC/50-60Hz ,current〈5mA |
|
Operation voltage: 85V to 125V for 110V and 190V to 250V for 220V |
|
Operation Temperature: -10° C to 60° C |
|
Operation Humidity: 20% to 85% |
|
Long life running and enargy saving products |
|
Design to cooling communication equipment, computer system, large generator and |
|
motor, industry: paint workshop, warehouse, machinery, kitchens |
|
Usually used for air supply and air suction of A/C unit, condenser, |
|
evaporator, compressor, main air extraction for residences, office, laboratories |
|
|
|
|
|